留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 18 Issue 2
Apr.  2011
数据统计

分享

计量
  • 文章访问数:  214
  • HTML全文浏览量:  43
  • PDF下载量:  14
  • 被引次数: 0
Jian-long Zhou, Xiao-gang Li, Cui-wei Du, Ying Pan, Tao Li, and Qian Liu, Passivation process of X80 pipeline steel in bicarbonate solutions, Int. J. Miner. Metall. Mater., 18(2011), No. 2, pp. 178-184. https://doi.org/10.1007/s12613-011-0419-8
Cite this article as:
Jian-long Zhou, Xiao-gang Li, Cui-wei Du, Ying Pan, Tao Li, and Qian Liu, Passivation process of X80 pipeline steel in bicarbonate solutions, Int. J. Miner. Metall. Mater., 18(2011), No. 2, pp. 178-184. https://doi.org/10.1007/s12613-011-0419-8
引用本文 PDF XML SpringerLink

Passivation process of X80 pipeline steel in bicarbonate solutions

  • 通讯作者:

    Xiao-gang Li    E-mail: lixiaogang99@263.net

  • The passivation process of X80 pipeline steel in bicarbonate solutions was investigated using potentiodynamic, dynamic electrochemical impedance spectroscopy (DEIS), and Mott-Schottky measurements. The results show that the shape of polarization curves changes with HCO3- concentration. The critical ‘passive’ concentration is 0.009 mol/L HCO3- for X80 pipeline steel in bicarbonate solutions. No anodic current peak exists in HCO3- solutions when the concentration is lower than 0.009 mol/L, whereas there are one and two anodic current peaks when the HCO3- concentration ranges from 0.009 to 0.05 mol/L and is higher than 0.1 mol/L, respectively. DEIS measurements show that there exist active dissolution range, transition range, pre-passive range, passive layer formation range, passive range, and trans-passive range for X80 pipeline steel in the 0.1 mol/L HCO3- solutions. The results of DEIS measurements are in complete agreement with the potentiodynamic diagram. An equivalent circuit containing three sub-layers is used to explain the Nyquist plots in the passive range. Analyses are well made for explaining the corresponding fitted capacitance and impedance. The Mott-Schottky plots show that the passive film of X80 pipeline steel is an n-type semiconductor, and capacitance measurements are in good accordance with the results of DEIS experiment.
  • Passivation process of X80 pipeline steel in bicarbonate solutions

    + Author Affiliations
    • The passivation process of X80 pipeline steel in bicarbonate solutions was investigated using potentiodynamic, dynamic electrochemical impedance spectroscopy (DEIS), and Mott-Schottky measurements. The results show that the shape of polarization curves changes with HCO3- concentration. The critical ‘passive’ concentration is 0.009 mol/L HCO3- for X80 pipeline steel in bicarbonate solutions. No anodic current peak exists in HCO3- solutions when the concentration is lower than 0.009 mol/L, whereas there are one and two anodic current peaks when the HCO3- concentration ranges from 0.009 to 0.05 mol/L and is higher than 0.1 mol/L, respectively. DEIS measurements show that there exist active dissolution range, transition range, pre-passive range, passive layer formation range, passive range, and trans-passive range for X80 pipeline steel in the 0.1 mol/L HCO3- solutions. The results of DEIS measurements are in complete agreement with the potentiodynamic diagram. An equivalent circuit containing three sub-layers is used to explain the Nyquist plots in the passive range. Analyses are well made for explaining the corresponding fitted capacitance and impedance. The Mott-Schottky plots show that the passive film of X80 pipeline steel is an n-type semiconductor, and capacitance measurements are in good accordance with the results of DEIS experiment.
    • loading

    Catalog


    • /

      返回文章
      返回