留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 23 Issue 1
Jan.  2016
数据统计

分享

计量
  • 文章访问数:  364
  • HTML全文浏览量:  91
  • PDF下载量:  14
  • 被引次数: 0
Li-hua Zhao, Lu Lin,  and Qi-fan Wu, Experimental study on sulfur removal from ladle furnace refining slag in hot state by blowing air, Int. J. Miner. Metall. Mater., 23(2016), No. 1, pp. 33-39. https://doi.org/10.1007/s12613-016-1208-1
Cite this article as:
Li-hua Zhao, Lu Lin,  and Qi-fan Wu, Experimental study on sulfur removal from ladle furnace refining slag in hot state by blowing air, Int. J. Miner. Metall. Mater., 23(2016), No. 1, pp. 33-39. https://doi.org/10.1007/s12613-016-1208-1
引用本文 PDF XML SpringerLink

Experimental study on sulfur removal from ladle furnace refining slag in hot state by blowing air

  • 通讯作者:

    Li-hua Zhao    E-mail: zhaolihua@metall.ustb.edu.cn

  • In view of the present problem of sulfur enrichment in the metallurgical recycling process of ladle furnace (LF) refining slag, a simple and efficient method of removing sulfur from this slag was proposed. The proposed method is compatible with current steelmaking processes. Sulfur removal from LF refining slag for SPHC steel (manufactured at a certain steel plant in China) by blowing air in the hot state was studied by using hot-state experiments in a laboratory. The FactSage software, a carbon/sulfur analyzer, and scanning electron microscopy in conjunction with energy-dispersive X-ray spectroscopy were used to test and analyze the sulfur removal effect and to investigate factors influencing sulfur removal rate. The results show that sulfur ions in LF refining slag can be oxidized into SO2 by O2 at high temperature by blowing air into molten slag; SO2 production was observed to reach a maximum with a small amount of blown O2 when the temperature exceeded 1350℃. At 1370℃ and 1400℃, experimental LF refining slag is in the liquid state and exhibits good fluidity; under these conditions, the sulfur removal effect by blowing air is greater than 90wt% after 60 min. High temperature and large air flow rate are beneficial for removing sulfur from LF refining slag; compared with air flow rate, temperature has a greater strongly influences on the sulfur removal.
  • Experimental study on sulfur removal from ladle furnace refining slag in hot state by blowing air

    + Author Affiliations
    • In view of the present problem of sulfur enrichment in the metallurgical recycling process of ladle furnace (LF) refining slag, a simple and efficient method of removing sulfur from this slag was proposed. The proposed method is compatible with current steelmaking processes. Sulfur removal from LF refining slag for SPHC steel (manufactured at a certain steel plant in China) by blowing air in the hot state was studied by using hot-state experiments in a laboratory. The FactSage software, a carbon/sulfur analyzer, and scanning electron microscopy in conjunction with energy-dispersive X-ray spectroscopy were used to test and analyze the sulfur removal effect and to investigate factors influencing sulfur removal rate. The results show that sulfur ions in LF refining slag can be oxidized into SO2 by O2 at high temperature by blowing air into molten slag; SO2 production was observed to reach a maximum with a small amount of blown O2 when the temperature exceeded 1350℃. At 1370℃ and 1400℃, experimental LF refining slag is in the liquid state and exhibits good fluidity; under these conditions, the sulfur removal effect by blowing air is greater than 90wt% after 60 min. High temperature and large air flow rate are beneficial for removing sulfur from LF refining slag; compared with air flow rate, temperature has a greater strongly influences on the sulfur removal.
    • loading

    Catalog


    • /

      返回文章
      返回