留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 13 Issue 2
Apr.  2006
数据统计

分享

计量
  • 文章访问数:  178
  • HTML全文浏览量:  46
  • PDF下载量:  8
  • 被引次数: 0
Dequan Peng, Xinde Bai, and Baoshan Chen, Effect of copper ions implantation on the corrosion behavior of ZIRLO alloy in 1 mol/L H2SO4, J. Univ. Sci. Technol. Beijing, 13(2006), No. 2, pp. 158-163. https://doi.org/10.1016/S1005-8850(06)60035-2
Cite this article as:
Dequan Peng, Xinde Bai, and Baoshan Chen, Effect of copper ions implantation on the corrosion behavior of ZIRLO alloy in 1 mol/L H2SO4, J. Univ. Sci. Technol. Beijing, 13(2006), No. 2, pp. 158-163. https://doi.org/10.1016/S1005-8850(06)60035-2
引用本文 PDF XML SpringerLink
Materials

Effect of copper ions implantation on the corrosion behavior of ZIRLO alloy in 1 mol/L H2SO4

  • 通讯作者:

    Dequan Peng    E-mail: pdq01@mails.tsinghua.edu.cn

  • In order to study the effect of copper ion implantation on the aqueous corrosion behavior of ZIRLO alloy, specimens were implanted with copper ions with fluences ranging from 1×1016 to 1×1017 ions/cm2, using a metal vapor vacuum arc source (MEVVA) at an extraction voltage of 40 kV. The valence states and depth distributions of elements in the surface layer of the samples were analyzed by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES), respectively. Glancing angle X-ray diffraction (GAXRD) was employed to examine the phase transformation due to the copper ion implantation. The potentiodynamic polarization technique was used to evaluate the aqueous corrosion resistance of implanted ZIRLO alloy in a 1 mol/L H2SO4 solution. It was found that a significant improvement was achieved in the aqueous corrosion resistance of ZIRLO alloy implanted with copper ions when the fluence is 5×1016 ions/cm2. When the fluence is 1×1016 or 1×1017 ions/cm2, the corrosion resistance of implanted samples was bad. Finally, the mechanism of the corrosion behavior of copper-implanted ZIRLO alloy was discussed.
  • Materials

    Effect of copper ions implantation on the corrosion behavior of ZIRLO alloy in 1 mol/L H2SO4

    + Author Affiliations
    • In order to study the effect of copper ion implantation on the aqueous corrosion behavior of ZIRLO alloy, specimens were implanted with copper ions with fluences ranging from 1×1016 to 1×1017 ions/cm2, using a metal vapor vacuum arc source (MEVVA) at an extraction voltage of 40 kV. The valence states and depth distributions of elements in the surface layer of the samples were analyzed by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES), respectively. Glancing angle X-ray diffraction (GAXRD) was employed to examine the phase transformation due to the copper ion implantation. The potentiodynamic polarization technique was used to evaluate the aqueous corrosion resistance of implanted ZIRLO alloy in a 1 mol/L H2SO4 solution. It was found that a significant improvement was achieved in the aqueous corrosion resistance of ZIRLO alloy implanted with copper ions when the fluence is 5×1016 ions/cm2. When the fluence is 1×1016 or 1×1017 ions/cm2, the corrosion resistance of implanted samples was bad. Finally, the mechanism of the corrosion behavior of copper-implanted ZIRLO alloy was discussed.
    • loading

    Catalog


    • /

      返回文章
      返回