留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 15 Issue 3
Jun.  2008
数据统计

分享

计量
  • 文章访问数:  347
  • HTML全文浏览量:  116
  • PDF下载量:  6
  • 被引次数: 0
Dequan Peng, Xinde Bai, and Feng Pan, Irradiation damage simulation of Zircaloy-4 using argon ions bombardment, J. Univ. Sci. Technol. Beijing, 15(2008), No. 3, pp. 285-289. https://doi.org/10.1016/S1005-8850(08)60054-7
Cite this article as:
Dequan Peng, Xinde Bai, and Feng Pan, Irradiation damage simulation of Zircaloy-4 using argon ions bombardment, J. Univ. Sci. Technol. Beijing, 15(2008), No. 3, pp. 285-289. https://doi.org/10.1016/S1005-8850(08)60054-7
引用本文 PDF XML SpringerLink
Materials

Irradiation damage simulation of Zircaloy-4 using argon ions bombardment

  • 通讯作者:

    Dequan Peng    E-mail: pdq01@mails.tsinghua.edu.cn

  • To simulate irradiation damage, argon ion was implanted in the Zircaloy-4 with the fluence ranging from 1×1016 to 1×1017 cm-2, using accelerating implanter at an extraction voltage of 190 kV and liquid nitrogen temperature. Then the influence of argon ion implantation on the aqueous corrosion behavior of Zircaloy-4 was studied. The valence states of elements in the surface layer of the samples were analyzed using X-ray photoelectron spectroscopy (XPS). Transmission electron microscopy (TEM) was used to examine the microstructure of the argon-implanted samples. The potentiodynamic polarization technique was employed to evaluate the aqueous corrosion resistance of implanted Zircaloy-4 in 1 mol/L HzSO4 solution. It is found that there appear bubbles on the surface of the samples when the argon fluence is 1×1016 cm-2. The microstructure of argon-implanted samples changes from amorphous to partial amorphous, then to polycrystalline, and again to amorphous. The corrosion resistance of implanted samples linearly declines with the increase of fluence approximately, which is attributed to the linear increase of the irradiation damage.
  • Materials

    Irradiation damage simulation of Zircaloy-4 using argon ions bombardment

    + Author Affiliations
    • To simulate irradiation damage, argon ion was implanted in the Zircaloy-4 with the fluence ranging from 1×1016 to 1×1017 cm-2, using accelerating implanter at an extraction voltage of 190 kV and liquid nitrogen temperature. Then the influence of argon ion implantation on the aqueous corrosion behavior of Zircaloy-4 was studied. The valence states of elements in the surface layer of the samples were analyzed using X-ray photoelectron spectroscopy (XPS). Transmission electron microscopy (TEM) was used to examine the microstructure of the argon-implanted samples. The potentiodynamic polarization technique was employed to evaluate the aqueous corrosion resistance of implanted Zircaloy-4 in 1 mol/L HzSO4 solution. It is found that there appear bubbles on the surface of the samples when the argon fluence is 1×1016 cm-2. The microstructure of argon-implanted samples changes from amorphous to partial amorphous, then to polycrystalline, and again to amorphous. The corrosion resistance of implanted samples linearly declines with the increase of fluence approximately, which is attributed to the linear increase of the irradiation damage.
    • loading