留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 16 Issue 2
Apr.  2009
数据统计

分享

计量
  • 文章访问数:  239
  • HTML全文浏览量:  65
  • PDF下载量:  10
  • 被引次数: 0
Shu-Huei Hsieh and Wen-Jauh Chen, Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath, Int. J. Miner. Metall. Mater., 16(2009), No. 2, pp. 197-202. https://doi.org/10.1016/S1674-4799(09)60033-9
Cite this article as:
Shu-Huei Hsieh and Wen-Jauh Chen, Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath, Int. J. Miner. Metall. Mater., 16(2009), No. 2, pp. 197-202. https://doi.org/10.1016/S1674-4799(09)60033-9
引用本文 PDF XML SpringerLink
Materials

Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath

  • 通讯作者:

    Wen-Jauh Chen    E-mail: chenwjau@yuntech.edu.tw

  • Electroless Ni-Cu-P deposits were deposited on the Si substrate in a basic hypophosphite-type plating bath. The effects of pH value and the metal source composition, Ni and Cu, in the plating bath on the kinetics of the Ni-Cu-P deposition were studied. The electroless Ni-Cu-P deposits were characterized by a scanning electron microscope, a transmission electron microscope, an energy dispersive X-ray spectroscope, and an X-ray diffractometer. The results showed that the pH value of the plating bath had no obvious effect on the morphology and composition of electroless Ni-Cu-P deposits. However, the composition of the metal source, Ni and Cu, in the plating bath had great effect on the kinetics of electroless Ni-Cu-P deposition.
  • Materials

    Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath

    + Author Affiliations
    • Electroless Ni-Cu-P deposits were deposited on the Si substrate in a basic hypophosphite-type plating bath. The effects of pH value and the metal source composition, Ni and Cu, in the plating bath on the kinetics of the Ni-Cu-P deposition were studied. The electroless Ni-Cu-P deposits were characterized by a scanning electron microscope, a transmission electron microscope, an energy dispersive X-ray spectroscope, and an X-ray diffractometer. The results showed that the pH value of the plating bath had no obvious effect on the morphology and composition of electroless Ni-Cu-P deposits. However, the composition of the metal source, Ni and Cu, in the plating bath had great effect on the kinetics of electroless Ni-Cu-P deposition.
    • loading

    Catalog


    • /

      返回文章
      返回