留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 16 Issue 3
Jun.  2009
数据统计

分享

计量
  • 文章访问数:  308
  • HTML全文浏览量:  92
  • PDF下载量:  16
  • 被引次数: 0
Jik-chang Leong, Kai-wun Jin, Jia-shyan Shiau, Tzer-ming Jeng, and Chang-hsien Tai, Effect of sinter layer porosity distribution on flow and temperature fields in a sinter cooler, Int. J. Miner. Metall. Mater., 16(2009), No. 3, pp. 265-272. https://doi.org/10.1016/S1674-4799(09)60048-0
Cite this article as:
Jik-chang Leong, Kai-wun Jin, Jia-shyan Shiau, Tzer-ming Jeng, and Chang-hsien Tai, Effect of sinter layer porosity distribution on flow and temperature fields in a sinter cooler, Int. J. Miner. Metall. Mater., 16(2009), No. 3, pp. 265-272. https://doi.org/10.1016/S1674-4799(09)60048-0
引用本文 PDF XML SpringerLink
Metallurgy

Effect of sinter layer porosity distribution on flow and temperature fields in a sinter cooler

  • 通讯作者:

    Chang-hsien Tai    E-mail: chtai@mail.npust.edu.tw

  • When sinters are filled into the sinter cooler from the sintering machine, it is commonly seen that, due to segregation effects, sinters of larger size usually accumulate closer to the inner wall of the sinter cooler, whereas those of smaller size are to the outer wall. This nonuniform distribution of sinters has led to uneven cooling effect throughout the cooler. This causes the sinters leaving the cooler at a large temperature difference. This undesired temperature difference leads to the deformation and even the destruction of the conveyors. The computational fluid dynamics (CFD) technique was used in the present work to investigate the heat and fluid flow phenomena within the sinter cooler corresponding to the different distribution of sinter layer porosity, which was highly dependent on the arrangement and orientation of sinters within the sinter cooler. It is confirmed that a high mass flow rate within the sinter layer causes a low temperature region and vice versa. The flow fields for vertically reducing porosity distribution and random distribution are almost identical indicating the relative insignificance of convective heat transfer mechanism.
  • Metallurgy

    Effect of sinter layer porosity distribution on flow and temperature fields in a sinter cooler

    + Author Affiliations
    • When sinters are filled into the sinter cooler from the sintering machine, it is commonly seen that, due to segregation effects, sinters of larger size usually accumulate closer to the inner wall of the sinter cooler, whereas those of smaller size are to the outer wall. This nonuniform distribution of sinters has led to uneven cooling effect throughout the cooler. This causes the sinters leaving the cooler at a large temperature difference. This undesired temperature difference leads to the deformation and even the destruction of the conveyors. The computational fluid dynamics (CFD) technique was used in the present work to investigate the heat and fluid flow phenomena within the sinter cooler corresponding to the different distribution of sinter layer porosity, which was highly dependent on the arrangement and orientation of sinters within the sinter cooler. It is confirmed that a high mass flow rate within the sinter layer causes a low temperature region and vice versa. The flow fields for vertically reducing porosity distribution and random distribution are almost identical indicating the relative insignificance of convective heat transfer mechanism.
    • loading

    Catalog


    • /

      返回文章
      返回