Liang-liang Guo, Yong Tian, Man Yao, and Hou-fa Shen, Temperature distribution and dynamic control of secondary cooling in slab continuous casting, Int. J. Miner. Metall. Mater., 16(2009), No. 6, pp. 626-631. https://doi.org/10.1016/S1674-4799(10)60003-9
Cite this article as:
Liang-liang Guo, Yong Tian, Man Yao, and Hou-fa Shen, Temperature distribution and dynamic control of secondary cooling in slab continuous casting, Int. J. Miner. Metall. Mater., 16(2009), No. 6, pp. 626-631. https://doi.org/10.1016/S1674-4799(10)60003-9
引用本文 PDF XML SpringerLink
Metallurgy

Temperature distribution and dynamic control of secondary cooling in slab continuous casting

  • 通讯作者:

    Hou-fa Shen    E-mail: shen@tsinghua.edu.cn

  • To predict and optimize the temperature distribution of slab continuous casting in steady operational state, a three-dimensional model (named "offline model") based on the heat transfer and solidification theories was developed. Both heat transfer and flux distribution characteristics of the nozzle sprays on the slab were considered, and the complicated boundary conditions, such as spray cooling, natural convection, thermal radiation as well as contact cooling of individual rolls were involved in the model. By using the calibrated caster dependent model factors, the calculated temperature and shell thickness accorded well with the measured. Furthermore, a dynamic secondary water cooling control system was also developed on the basis of a two-dimensional transient heat transfer model (named "online model") and incremental PID control algorithm to reduce slab surface temperature fluctuation in unsteady state. Compared with the traditional spray table control method, the present online model and dynamic PID control demonstrate a higher capability and flexibility to adjust cooling water flowrate and reduce slab surface temperature fluctuation when the casting speed is changed.
  • Metallurgy

    Temperature distribution and dynamic control of secondary cooling in slab continuous casting

    + Author Affiliations
    • To predict and optimize the temperature distribution of slab continuous casting in steady operational state, a three-dimensional model (named "offline model") based on the heat transfer and solidification theories was developed. Both heat transfer and flux distribution characteristics of the nozzle sprays on the slab were considered, and the complicated boundary conditions, such as spray cooling, natural convection, thermal radiation as well as contact cooling of individual rolls were involved in the model. By using the calibrated caster dependent model factors, the calculated temperature and shell thickness accorded well with the measured. Furthermore, a dynamic secondary water cooling control system was also developed on the basis of a two-dimensional transient heat transfer model (named "online model") and incremental PID control algorithm to reduce slab surface temperature fluctuation in unsteady state. Compared with the traditional spray table control method, the present online model and dynamic PID control demonstrate a higher capability and flexibility to adjust cooling water flowrate and reduce slab surface temperature fluctuation when the casting speed is changed.