留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 10 Issue 1
Feb.  2003
数据统计

分享

计量
  • 文章访问数:  246
  • HTML全文浏览量:  84
  • PDF下载量:  11
  • 被引次数: 0
Changsheng Peng, Hong Meng, Jinglai Zhang, and Shouci Lu, Treatment of electroplating wastewater, J. Univ. Sci. Technol. Beijing, 10(2003), No. 1, pp. 8-11.
Cite this article as:
Changsheng Peng, Hong Meng, Jinglai Zhang, and Shouci Lu, Treatment of electroplating wastewater, J. Univ. Sci. Technol. Beijing, 10(2003), No. 1, pp. 8-11.
引用本文 PDF XML SpringerLink
Mineral

Treatment of electroplating wastewater

  • 通讯作者:

    Changsheng Peng    E-mail: cspeng@sohu.com

  • To study the feasibility of treated water being used as rinsing water with CP/ED (chemical precipitation/ electrodialysis) system, the relation between concentration of Cr (Ⅵ) and conductivity of water is investigated, the effect of electrodialysis (ED) for different wastewater is also studied. And several parameters of importance that are relevant to the process are identified. Analysis of ICP (Inductively coupled plasma) and IC (Ion chromatography) shows that the main reason of conductivity increase in CP treated water is the increase of Na+ and Cl- ions. The 93.8%-100% of ions from wastewater both in ED and CP/ED systems was removed successfully. The results of experiments indicate that the CP/ED system is a feasible method for electroplating wastewater treatment, the CP/ED system used as a way of wastwater is not only in favour of environment, but also economic beneficial to achieve.
  • Mineral

    Treatment of electroplating wastewater

    + Author Affiliations
    • To study the feasibility of treated water being used as rinsing water with CP/ED (chemical precipitation/ electrodialysis) system, the relation between concentration of Cr (Ⅵ) and conductivity of water is investigated, the effect of electrodialysis (ED) for different wastewater is also studied. And several parameters of importance that are relevant to the process are identified. Analysis of ICP (Inductively coupled plasma) and IC (Ion chromatography) shows that the main reason of conductivity increase in CP treated water is the increase of Na+ and Cl- ions. The 93.8%-100% of ions from wastewater both in ED and CP/ED systems was removed successfully. The results of experiments indicate that the CP/ED system is a feasible method for electroplating wastewater treatment, the CP/ED system used as a way of wastwater is not only in favour of environment, but also economic beneficial to achieve.
    • loading

    Catalog


    • /

      返回文章
      返回