HUANG KEQIN, XIA YUHUA, and LIU QINGGUO, SEEBECK EFFECT IN OXYGEN PROBE USED FOROXYGEN DETERMINATION IN LIQUID STEEL, J. Univ. Sci. Technol. Beijing , 2(1995), No. 1, pp.57-62.
HUANG KEQIN, XIA YUHUA, and LIU QINGGUO, SEEBECK EFFECT IN OXYGEN PROBE USED FOROXYGEN DETERMINATION IN LIQUID STEEL, J. Univ. Sci. Technol. Beijing , 2(1995), No. 1, pp.57-62.
引用本文 PDF XML SpringerLink

钢液定氧测头中的Seebeck效应

摘要: 采用非稳态法对钢液定氧测头中的传热过程进行了分析,并使用"双测头"方式对该过程进行了测量。结果表明,在钢液定氧测头的响应过程中,温差热电势随时间呈负指数变化,在低氧条件下Seebeck系数和固体电解质的传热系数与文献值吻合较好。

 

SEEBECK EFFECT IN OXYGEN PROBE USED FOROXYGEN DETERMINATION IN LIQUID STEEL

Abstract: Heat conduction in oxygen probe was analyzed by means of non-steady state method and measured using "double probe" arrangement. The results showed that during the response process the thermal emf was decreased exponentially with the time and in case of low oxygen level the Seebeck coefficient and thermal conductivity of solid electrolyte agreed well with those in literatures.

 

/