留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 9 Issue 5
Oct.  2002
数据统计

分享

计量
  • 文章访问数:  230
  • HTML全文浏览量:  75
  • PDF下载量:  8
  • 被引次数: 0
Bo Li, Nuo Ma, Xinlin Wang, Kang An, Hongwei Qin, and Jifan Hu, Giant magnetoimpedance effect in as quenched Fe89-xZr7B4Cux(x=1.0-2.5) ribbons, J. Univ. Sci. Technol. Beijing, 9(2002), No. 5, pp. 383-385.
Cite this article as:
Bo Li, Nuo Ma, Xinlin Wang, Kang An, Hongwei Qin, and Jifan Hu, Giant magnetoimpedance effect in as quenched Fe89-xZr7B4Cux(x=1.0-2.5) ribbons, J. Univ. Sci. Technol. Beijing, 9(2002), No. 5, pp. 383-385.
引用本文 PDF XML SpringerLink
Materials

Giant magnetoimpedance effect in as quenched Fe89-xZr7B4Cux(x=1.0-2.5) ribbons

  • 通讯作者:

    Bo Li    E-mail: Libo@atmcn.com

  • The giant magnetoimpedance (GMI) effect in as-quenched Fe89-xZr7B4Cux (x=1.0-2.5) ribbons is reported. The as-quenched Fe89-xZr7B4Cux (x=1.0-2.5) ribbons were prepared by the vacuum melt-spun processes withthe quenching speed of 37m/s. The magnetoimpedance measurement were performed at room temperature, where the current flows through the length of the ribbons in the direction parallel to the dc fields. Results show that values Z (impedance), R (resistance) and X (reactance) forboth H=0 A/m and H=5 127 A/m increases with increasing ac frequency. This can be explained by the skin effect mechanism. The GMI effect almostcan not be found in the Cu content (mass fraction) range x ≤ 1.5%. With increasing Cu content x > 1.5%, the GMI effect become evident for as-quenched Fe89-xZr7B4Cux (x=1.0-2.5) ribbons. GMI ratio (Z(0)Z(H)/Z(0)) in as quenched Fe86.5Zr7B4Cu2.5 with melt-spun quenching speed of canreaches 33.69% at H=5 127 A/m. This indicated that good GMI properties can be also obtained in as-quenched FeZrBCu ribbons without annealing.
  • Materials

    Giant magnetoimpedance effect in as quenched Fe89-xZr7B4Cux(x=1.0-2.5) ribbons

    + Author Affiliations
    • The giant magnetoimpedance (GMI) effect in as-quenched Fe89-xZr7B4Cux (x=1.0-2.5) ribbons is reported. The as-quenched Fe89-xZr7B4Cux (x=1.0-2.5) ribbons were prepared by the vacuum melt-spun processes withthe quenching speed of 37m/s. The magnetoimpedance measurement were performed at room temperature, where the current flows through the length of the ribbons in the direction parallel to the dc fields. Results show that values Z (impedance), R (resistance) and X (reactance) forboth H=0 A/m and H=5 127 A/m increases with increasing ac frequency. This can be explained by the skin effect mechanism. The GMI effect almostcan not be found in the Cu content (mass fraction) range x ≤ 1.5%. With increasing Cu content x > 1.5%, the GMI effect become evident for as-quenched Fe89-xZr7B4Cux (x=1.0-2.5) ribbons. GMI ratio (Z(0)Z(H)/Z(0)) in as quenched Fe86.5Zr7B4Cu2.5 with melt-spun quenching speed of canreaches 33.69% at H=5 127 A/m. This indicated that good GMI properties can be also obtained in as-quenched FeZrBCu ribbons without annealing.
    • loading

    Catalog


    • /

      返回文章
      返回