留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 12 Issue 1
Feb.  2005
数据统计

分享

计量
  • 文章访问数:  479
  • HTML全文浏览量:  125
  • PDF下载量:  15
  • 被引次数: 0
Kexin Zhao, Minggang Shen, and Xueda Wang, Simulation of inside-grooved mould improving heat transfer of original shell of casting slab, J. Univ. Sci. Technol. Beijing, 12(2005), No. 1, pp. 23-25.
Cite this article as:
Kexin Zhao, Minggang Shen, and Xueda Wang, Simulation of inside-grooved mould improving heat transfer of original shell of casting slab, J. Univ. Sci. Technol. Beijing, 12(2005), No. 1, pp. 23-25.
引用本文 PDF XML SpringerLink
Metallurgy

Simulation of inside-grooved mould improving heat transfer of original shell of casting slab

  • 通讯作者:

    Kexin Zhao    E-mail: Kexinzhao1978@sohu.com

  • The dipping experiment was carried out by putting the water-cooled copper plate into the stannum-lead alloy to simulate the process of initial solidification of steel, and the result that the heat transfer of original shell improved by grooving on the surface of the water-cooled copper plate was investigated. A mathematical model of heat transfer was set up and the temperature field of casting slab 1000 mm×200mm was calculated. The experimentation and simulation results indicate that the inside-grooved mould could improve the heat transfer of original shell, decrease the non-uniformity of original shell thickness and reduce the longitudinal surface cracks of casting slab.
  • Metallurgy

    Simulation of inside-grooved mould improving heat transfer of original shell of casting slab

    + Author Affiliations
    • The dipping experiment was carried out by putting the water-cooled copper plate into the stannum-lead alloy to simulate the process of initial solidification of steel, and the result that the heat transfer of original shell improved by grooving on the surface of the water-cooled copper plate was investigated. A mathematical model of heat transfer was set up and the temperature field of casting slab 1000 mm×200mm was calculated. The experimentation and simulation results indicate that the inside-grooved mould could improve the heat transfer of original shell, decrease the non-uniformity of original shell thickness and reduce the longitudinal surface cracks of casting slab.
    • loading

    Catalog


    • /

      返回文章
      返回