Tao Feng, Songnian Lou, Luhai Wu, and Yajiang Li, XRD and TEM analysis of the microstructure in the brazing joint of 3003 cladding aluminum alloy, J. Univ. Sci. Technol. Beijing, 12(2005), No. 6, pp. 531-534.
Cite this article as:
Tao Feng, Songnian Lou, Luhai Wu, and Yajiang Li, XRD and TEM analysis of the microstructure in the brazing joint of 3003 cladding aluminum alloy, J. Univ. Sci. Technol. Beijing, 12(2005), No. 6, pp. 531-534.
引用本文 PDF XML SpringerLink
Materials

XRD and TEM analysis of the microstructure in the brazing joint of 3003 cladding aluminum alloy

  • 通讯作者:

    Tao Feng    E-mail: ft_210750@sina.com.cn

  • The material used in this experiment was 3003 cladding aluminum alloy, the cladding metal was 4004 aluminum alloy. The aluminum plate was brazed by means of vacuum brazing. The microstructure in the brazing joint was studied by means of X-ray diffractometry (XRD) and transmission electron microscopy (TEM). The test result indicates that the suitable brazing technique parameters are brazing temperature, 628°C; keeping time, 10 min; vacuum degree, 6.5×10-4 Pa. XRD test indicates that there are new intermetallic compounds different from the base metal. TEM analysis indicates that Cu2Mg and Cu3Mn2Mg are formed in the brazing joint. The shape of Cu2Mg is irregular and the shape of Cu3Mn2Mg is circle, and there are tiny particles in it.
  • Materials

    XRD and TEM analysis of the microstructure in the brazing joint of 3003 cladding aluminum alloy

    + Author Affiliations
    • The material used in this experiment was 3003 cladding aluminum alloy, the cladding metal was 4004 aluminum alloy. The aluminum plate was brazed by means of vacuum brazing. The microstructure in the brazing joint was studied by means of X-ray diffractometry (XRD) and transmission electron microscopy (TEM). The test result indicates that the suitable brazing technique parameters are brazing temperature, 628°C; keeping time, 10 min; vacuum degree, 6.5×10-4 Pa. XRD test indicates that there are new intermetallic compounds different from the base metal. TEM analysis indicates that Cu2Mg and Cu3Mn2Mg are formed in the brazing joint. The shape of Cu2Mg is irregular and the shape of Cu3Mn2Mg is circle, and there are tiny particles in it.