Zhang-jian Zhou, Jun Tan, Dan-dan Qu, Hua Li, Young-jin Yum, and Hyun-woo Lim, High heat loading performance of actively cooled W/Cu FGM-based components, Int. J. Miner. Metall. Mater., 18(2011), No. 4, pp. 467-471. https://doi.org/10.1007/s12613-011-0464-3
Cite this article as:
Zhang-jian Zhou, Jun Tan, Dan-dan Qu, Hua Li, Young-jin Yum, and Hyun-woo Lim, High heat loading performance of actively cooled W/Cu FGM-based components, Int. J. Miner. Metall. Mater., 18(2011), No. 4, pp. 467-471. https://doi.org/10.1007/s12613-011-0464-3

High heat loading performance of actively cooled W/Cu FGM-based components

+ Author Affiliations
  • Corresponding author:

    Zhang-jian Zhou    E-mail: zhouzhj@mater.ustb.edu.cn

  • Received: 10 July 2010Revised: 17 September 2010Accepted: 25 September 2010
  • A functionally graded material-based actively water-cooled tungsten-copper mockup with a dimension of 30 mm×30 mm×25 mm was designed and fabricated by infiltration-brazing method. The thicknesses of the pure W layer and W/Cu graded layer were 2 and 3 mm, respectively. High heat flux tests were performed on the mockup using an e-beam device. There is no damage occurring on the joint after heat loading at 5 MW/m2. The temperature on the pure W surface is less than 500℃ after irradiation for 100 s at 5 MW/m2, while the temperature on the brazing seam/copper surface is around 200℃.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Share Article

    Article Metrics

    Article Views(172) PDF Downloads(7) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return