Ekarat Detsri, Sirilak Rujipornsakul, Tanapong Treetasayoot, and Pawarit Siriwattanamethanon, Nanostructured multilayer thin films of multiwalled carbon nanotubes/gold nanoparticles/glutathione for the electrochemical detection of dopamine, Int. J. Miner. Metall. Mater., 23(2016), No. 10, pp. 1204-1214. https://doi.org/10.1007/s12613-016-1340-y
Cite this article as:
Ekarat Detsri, Sirilak Rujipornsakul, Tanapong Treetasayoot, and Pawarit Siriwattanamethanon, Nanostructured multilayer thin films of multiwalled carbon nanotubes/gold nanoparticles/glutathione for the electrochemical detection of dopamine, Int. J. Miner. Metall. Mater., 23(2016), No. 10, pp. 1204-1214. https://doi.org/10.1007/s12613-016-1340-y

Nanostructured multilayer thin films of multiwalled carbon nanotubes/gold nanoparticles/glutathione for the electrochemical detection of dopamine

+ Author Affiliations
  • Corresponding author:

    Ekarat Detsri    E-mail: Ekarat.de@kmitl.ac.th

  • Received: 11 February 2016Revised: 19 April 2016Accepted: 30 May 2016
  • In the present study, multiwalled carbon nanotubes (MWCNTs), gold nanoparticles (AuNPs), and glutathione (GSH) were used to fabricate multilayer nanoscale thin films. The composite thin films were fabricated by layer-by-layer technique as the films were constructed by the alternate deposition of cationic and anionic polyelectrolytes. The MWCNTs were modified via a noncovalent surface modification method using poly(diallydimethylammonium chloride) to form a cationic polyelectrolyte. An anionic polyelectrolyte was prepared by the chemical reduction of HAuCl4 using sodium citrate as both the stabilizing and reducing agent to form anionic AuNPs. GSH was used as an electrocatalyst toward the electro-oxidation of dopamine. The constructed composite electrode exhibits excellent electrocatalytic activity toward dopamine with a short response time and a wide linear range from 1 to 100 μmol/L. The limits of detection and quantitation of dopamine are (0.316±0.081) μmol/L and (1.054±0.081) μmol/L, respectively. The method is satisfactorily applied for the determination of dopamine in plasma and urine samples to obtain the recovery in the range from 97.90% to 105.00%.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Share Article

    Article Metrics

    Article Views(353) PDF Downloads(24) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return