Shu-Huei Hsiehand Wen-Jauh Chen, Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath, Int. J. Miner. Metall. Mater., 16(2009), No. 2, pp. 197-202. https://doi.org/10.1016/S1674-4799(09)60033-9
Cite this article as:
Shu-Huei Hsiehand Wen-Jauh Chen, Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath, Int. J. Miner. Metall. Mater., 16(2009), No. 2, pp. 197-202. https://doi.org/10.1016/S1674-4799(09)60033-9
Shu-Huei Hsiehand Wen-Jauh Chen, Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath, Int. J. Miner. Metall. Mater., 16(2009), No. 2, pp. 197-202. https://doi.org/10.1016/S1674-4799(09)60033-9
Citation:
Shu-Huei Hsiehand Wen-Jauh Chen, Kinetics of electroless Ni-Cu-P deposits on silicon in a basic hypophosphite-type bath, Int. J. Miner. Metall. Mater., 16(2009), No. 2, pp. 197-202. https://doi.org/10.1016/S1674-4799(09)60033-9
Electroless Ni-Cu-P deposits were deposited on the Si substrate in a basic hypophosphite-type plating bath. The effects of pH value and the metal source composition, Ni and Cu, in the plating bath on the kinetics of the Ni-Cu-P deposition were studied. The electroless Ni-Cu-P deposits were characterized by a scanning electron microscope, a transmission electron microscope, an energy dispersive X-ray spectroscope, and an X-ray diffractometer. The results showed that the pH value of the plating bath had no obvious effect on the morphology and composition of electroless Ni-Cu-P deposits. However, the composition of the metal source, Ni and Cu, in the plating bath had great effect on the kinetics of electroless Ni-Cu-P deposition.