Changsheng Peng, Hong Meng, Jinglai Zhang,  and Shouci Lu, Treatment of electroplating wastewater, J. Univ. Sci. Technol. Beijing, 10(2003), No. 1, pp. 8-11.
Cite this article as:
Changsheng Peng, Hong Meng, Jinglai Zhang,  and Shouci Lu, Treatment of electroplating wastewater, J. Univ. Sci. Technol. Beijing, 10(2003), No. 1, pp. 8-11.
Mineral

Treatment of electroplating wastewater

+ Author Affiliations
  • Corresponding author:

    Changsheng Peng    E-mail: cspeng@sohu.com

  • Received: 8 April 2002
  • To study the feasibility of treated water being used as rinsing water with CP/ED (chemical precipitation/ electrodialysis) system, the relation between concentration of Cr (Ⅵ) and conductivity of water is investigated, the effect of electrodialysis (ED) for different wastewater is also studied. And several parameters of importance that are relevant to the process are identified. Analysis of ICP (Inductively coupled plasma) and IC (Ion chromatography) shows that the main reason of conductivity increase in CP treated water is the increase of Na+ and Cl- ions. The 93.8%-100% of ions from wastewater both in ED and CP/ED systems was removed successfully. The results of experiments indicate that the CP/ED system is a feasible method for electroplating wastewater treatment, the CP/ED system used as a way of wastwater is not only in favour of environment, but also economic beneficial to achieve.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Share Article

    Article Metrics

    Article Views(240) PDF Downloads(11) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return