Daqiang Cang, Yanbing Zong, Yixin Mao, Hao Bai, Jingpenng She,  and Keshi She, 3-D temperature distribution of a full size BF copper stave with oblate channel, J. Univ. Sci. Technol. Beijing, 10(2003), No. 3, pp. 13-15.
Cite this article as:
Daqiang Cang, Yanbing Zong, Yixin Mao, Hao Bai, Jingpenng She,  and Keshi She, 3-D temperature distribution of a full size BF copper stave with oblate channel, J. Univ. Sci. Technol. Beijing, 10(2003), No. 3, pp. 13-15.
Metallurgy

3-D temperature distribution of a full size BF copper stave with oblate channel

+ Author Affiliations
  • An experiment of a new type full size copper stave for a real blast furnace was carried out in a special-designed experimental system. The 3-D temperature distribution inside the stave including isotherm was obtained based on the experiment data. And the effects of the temperature of cooling water and the velocity of the water as well as the temperature of the furnace on the 3-D ternperature distribution were obtained. The experimental and calculation results show that the highest temperature of the hot surface is lower than 90℃ which is very good for the solidified slag formation on the hot surface and protecting the stave.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Share Article

    Article Metrics

    Article Views(222) PDF Downloads(8) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return