Chun-lei Gengand Duan Weng, A time-saving method to assess the efficiency of corrosion inhibitors by electro osmosis, Int. J. Miner. Metall. Mater., 18(2011), No. 3, pp. 370-376. https://doi.org/10.1007/s12613-011-0449-2
Cite this article as:
Chun-lei Gengand Duan Weng, A time-saving method to assess the efficiency of corrosion inhibitors by electro osmosis, Int. J. Miner. Metall. Mater., 18(2011), No. 3, pp. 370-376. https://doi.org/10.1007/s12613-011-0449-2
Chun-lei Gengand Duan Weng, A time-saving method to assess the efficiency of corrosion inhibitors by electro osmosis, Int. J. Miner. Metall. Mater., 18(2011), No. 3, pp. 370-376. https://doi.org/10.1007/s12613-011-0449-2
Citation:
Chun-lei Gengand Duan Weng, A time-saving method to assess the efficiency of corrosion inhibitors by electro osmosis, Int. J. Miner. Metall. Mater., 18(2011), No. 3, pp. 370-376. https://doi.org/10.1007/s12613-011-0449-2
The corrosion inhibitor is one of the most important technologies to enhance the durability of steel-reinforced concrete. A kind of time-saving method was developed to assess the inhibitor efficiency by using a 32 V electric field to accelerate chloride ion migration in concrete. Potentiodynamic polarization scanning test was used to evaluate the corrosion states. The comprehensive efficiency of an inhibitor should be assessed in two aspects: resistance to chloride ion permeability and inhibiting efficiency. The specimens with different mixing amount of sodium nitrite and migration corrosion inhibitors were used to verify the accuracy and reliability of this method. The results show the differences in inhibiting efficiency of the inhibitors clearly, indicating the reliability of this time-saving method.
The corrosion inhibitor is one of the most important technologies to enhance the durability of steel-reinforced concrete. A kind of time-saving method was developed to assess the inhibitor efficiency by using a 32 V electric field to accelerate chloride ion migration in concrete. Potentiodynamic polarization scanning test was used to evaluate the corrosion states. The comprehensive efficiency of an inhibitor should be assessed in two aspects: resistance to chloride ion permeability and inhibiting efficiency. The specimens with different mixing amount of sodium nitrite and migration corrosion inhibitors were used to verify the accuracy and reliability of this method. The results show the differences in inhibiting efficiency of the inhibitors clearly, indicating the reliability of this time-saving method.