摘要:
Cu-P-silicon carbide (SiC) composite coatings were deposited by means of electroless plating. The effects of pH values, temperature, and different concentrations of sodium hypophosphite (NaH
2PO
2·H
2O), nickel sulfate (NiSO
4·6H
2O), sodium citrate (C
6H
5Na
3O
7·2H
2O) and SiC on the deposition rate and coating compositions were evaluated, and the bath formulation for Cu-P-SiC composite coatings was optimised. The coating compositions were determined using energy-dispersive X-ray analysis (EDX). The corresponding optimal operating parameters for depositing Cu-P-SiC are as follows: pH 9; temperature, 90℃; NaH
2PO
2·H
2O concentration, 125 g/L; NiSO
4·6H
2O concentration, 3.125 g/L; SiC concentration, 5 g/L; and C
6H
5Na
3O
7·2H
2O concentration, 50 g/L. The surface morphology of the coatings analysed by scanning electron microscopy (SEM) shows that Cu particles are uniformly distributed. The hardness and wear resistance of Cu-P composite coatings are improved with the addition of SiC particles and increase with the increase of SiC content.