Anodic dissolution of a crack tip at AA2024-T351 in 3.5wt% NaCl solution

Hai Sheng, Chao-fang Dong, Kui Xiao, Xiao-gang Li, Lin Lu

分享

计量
  • 文章访问数:  246
  • HTML全文浏览量:  65
  • PDF下载量:  9
  • 被引次数: 0

目录

    Cite this article as:

    Hai Sheng, Chao-fang Dong, Kui Xiao, Xiao-gang Li, and Lin Lu, Anodic dissolution of a crack tip at AA2024-T351 in 3.5wt% NaCl solution, Int. J. Miner. Metall. Mater., 19(2012), No. 10, pp.939-944. https://dx.doi.org/10.1007/s12613-012-0651-x
    Hai Sheng, Chao-fang Dong, Kui Xiao, Xiao-gang Li, and Lin Lu, Anodic dissolution of a crack tip at AA2024-T351 in 3.5wt% NaCl solution, Int. J. Miner. Metall. Mater., 19(2012), No. 10, pp.939-944. https://dx.doi.org/10.1007/s12613-012-0651-x
    引用本文 PDF XML SpringerLink

    Anodic dissolution of a crack tip at AA2024-T351 in 3.5wt% NaCl solution

    基金项目: 

    This work was financially supported by the Fundamental Research Funds for the Central Universities (No.FRF-BR-10-037B) and the National Natural Science Foundation of China No.51131005].

      通信作者:

      Xiao-gang Li E-mail: lixiaogang99@263.net

    The anodic dissolution process of a crack tip at 2024-T351 aluminium alloy (AA2024-T351) was determined by means of scanning Kelvin probe (SKP). Wedge-open loading (WOL) specimens were immersed in a 3.5wt% NaCl solution. After various durations of immersion, the Volta potential distributions around the crack were measured by SKP and the surface morphologies were observed by scanning electron microscopy (SEM). It is found that there is a nonuniform distribution of Volta potential around the crack. Before immersion, the Volta potential at crack tip is more negative than that in other regions. However, after immersion, a converse result occurs with the most positive Volta potential measured at the crack tip. SEM observations demonstrate that the noticeable positive shift of Volta potential results from the formation of corrosion products which deposit around the crack tip. Energy-dispersive spectrometry (EDS) analysis shows that the corrosion products are mainly Al oxide and Cu-rich particles. These observations implicate that the applied stress contributes to the preferential anodic dissolution of the crack tip and the redistribution of Cu.

     

    Anodic dissolution of a crack tip at AA2024-T351 in 3.5wt% NaCl solution

    Author Affilications
    • Funds: 

      This work was financially supported by the Fundamental Research Funds for the Central Universities (No.FRF-BR-10-037B) and the National Natural Science Foundation of China No.51131005].

    • Received: 30 October 2011; Revised: 07 December 2011; Accepted: 14 December 2011;
    The anodic dissolution process of a crack tip at 2024-T351 aluminium alloy (AA2024-T351) was determined by means of scanning Kelvin probe (SKP). Wedge-open loading (WOL) specimens were immersed in a 3.5wt% NaCl solution. After various durations of immersion, the Volta potential distributions around the crack were measured by SKP and the surface morphologies were observed by scanning electron microscopy (SEM). It is found that there is a nonuniform distribution of Volta potential around the crack. Before immersion, the Volta potential at crack tip is more negative than that in other regions. However, after immersion, a converse result occurs with the most positive Volta potential measured at the crack tip. SEM observations demonstrate that the noticeable positive shift of Volta potential results from the formation of corrosion products which deposit around the crack tip. Energy-dispersive spectrometry (EDS) analysis shows that the corrosion products are mainly Al oxide and Cu-rich particles. These observations implicate that the applied stress contributes to the preferential anodic dissolution of the crack tip and the redistribution of Cu.

     

    /

    返回文章