留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 22 Issue 6
Jun.  2015
数据统计

分享

计量
  • 文章访问数:  284
  • HTML全文浏览量:  78
  • PDF下载量:  16
  • 被引次数: 0
Yu-bing Guo, Chong Li, Yong-chang Liu, Li-ming Yu, Zong-qing Ma, Chen-xi Liu,  and Hui-jun Li, Effect of microstructure variation on the corrosion behavior of high-strength low-alloy steel in 3.5wt% NaCl solution, Int. J. Miner. Metall. Mater., 22(2015), No. 6, pp. 604-612. https://doi.org/10.1007/s12613-015-1113-z
Cite this article as:
Yu-bing Guo, Chong Li, Yong-chang Liu, Li-ming Yu, Zong-qing Ma, Chen-xi Liu,  and Hui-jun Li, Effect of microstructure variation on the corrosion behavior of high-strength low-alloy steel in 3.5wt% NaCl solution, Int. J. Miner. Metall. Mater., 22(2015), No. 6, pp. 604-612. https://doi.org/10.1007/s12613-015-1113-z
引用本文 PDF XML SpringerLink

Effect of microstructure variation on the corrosion behavior of high-strength low-alloy steel in 3.5wt% NaCl solution

  • 通讯作者:

    Yong-chang Liu    E-mail: licmtju@163.com

  • The effect of microstructure variation on the corrosion behavior of high-strength low-alloy (HSLA) steel was investigated. The protective property of the corrosion product layer was also explored. Experimental results reveal that the type of microstructure has significant effect on the corrosion resistance of HSLA steel. The measurement results of weight loss, potentiodynamic polarization curves, and electrochemical impedance spectroscopy indicate that the steel with acicular ferrite microstructure exhibits the lowest corrosion rate. Martensite exhibits a reduced corrosion resistance compared with polygonal ferrite. It is found that the surface of the acicular ferrite specimen uniformly covered by corrosion products is seemingly denser and more compact than those of the other two microstructures, and can provide some amount of protection to the steel; thus, the charge transfer resistance and modulus values of the acicular ferrite specimen are the largest. However, corrosion products on martensite and polygonal ferrite are generally loose, porous, and defective, and can provide minor protectiveness; thus, the charge transfer resistance values for polygonal ferrite and martensite are lower.
  • Effect of microstructure variation on the corrosion behavior of high-strength low-alloy steel in 3.5wt% NaCl solution

    + Author Affiliations
    • The effect of microstructure variation on the corrosion behavior of high-strength low-alloy (HSLA) steel was investigated. The protective property of the corrosion product layer was also explored. Experimental results reveal that the type of microstructure has significant effect on the corrosion resistance of HSLA steel. The measurement results of weight loss, potentiodynamic polarization curves, and electrochemical impedance spectroscopy indicate that the steel with acicular ferrite microstructure exhibits the lowest corrosion rate. Martensite exhibits a reduced corrosion resistance compared with polygonal ferrite. It is found that the surface of the acicular ferrite specimen uniformly covered by corrosion products is seemingly denser and more compact than those of the other two microstructures, and can provide some amount of protection to the steel; thus, the charge transfer resistance and modulus values of the acicular ferrite specimen are the largest. However, corrosion products on martensite and polygonal ferrite are generally loose, porous, and defective, and can provide minor protectiveness; thus, the charge transfer resistance values for polygonal ferrite and martensite are lower.
    • loading

    Catalog


    • /

      返回文章
      返回