留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码
Volume 16 Issue 6
Dec.  2009
数据统计

分享

计量
  • 文章访问数:  239
  • HTML全文浏览量:  71
  • PDF下载量:  10
  • 被引次数: 0
Hua-bing Li, Zhou-hua Jiang, Zu-rui Zhang, Yang Cao, and Yan Yang, Intergranular corrosion behavior of high nitrogen austenitic stainless steel, Int. J. Miner. Metall. Mater., 16(2009), No. 6, pp. 654-660. https://doi.org/10.1016/S1674-4799(10)60008-8
Cite this article as:
Hua-bing Li, Zhou-hua Jiang, Zu-rui Zhang, Yang Cao, and Yan Yang, Intergranular corrosion behavior of high nitrogen austenitic stainless steel, Int. J. Miner. Metall. Mater., 16(2009), No. 6, pp. 654-660. https://doi.org/10.1016/S1674-4799(10)60008-8
引用本文 PDF XML SpringerLink
Materials

Intergranular corrosion behavior of high nitrogen austenitic stainless steel

  • 通讯作者:

    Zhou-hua Jiang    E-mail: jiangzh@smm.neu.edu.cn

  • The intergranular corrosion (IGC) behavior of high nitrogen austenitic stainless steel (HNSS) sensitization treated at 650-950℃ was investigated by the double loop electrochemical potentiodynamic reactivation (DL-EPR) method. The effects of the electrolytes, scan rate, sensitizing temperature on the susceptibility to IGC of HNSS were examined. The results show that the addi-tion of NaCl is an effective way to improve the formation of the cracking of a passive film in chromium-depleted zones during the reactivation scan. Decreasing the scan rate exhibits an obvious effect on the breakdown of the passive film. A solution with 2 mol/L H2SO4+1 mol/L NaCl+0.01 mol/L KSCN is suitable to check the susceptibility to IGC of HNSS at a sensitizing temperature of 650-950℃ at a suitable scan rate of 1.667 mV/s. Chromium depletion of HNSS is attributed to the precipitation of Cr2N which results in the susceptibility to IGC. The synergistic effect of Mo and N is suggested to play an important role in stabilizing the passive film to prevent the attack of IGC.
  • Materials

    Intergranular corrosion behavior of high nitrogen austenitic stainless steel

    + Author Affiliations
    • The intergranular corrosion (IGC) behavior of high nitrogen austenitic stainless steel (HNSS) sensitization treated at 650-950℃ was investigated by the double loop electrochemical potentiodynamic reactivation (DL-EPR) method. The effects of the electrolytes, scan rate, sensitizing temperature on the susceptibility to IGC of HNSS were examined. The results show that the addi-tion of NaCl is an effective way to improve the formation of the cracking of a passive film in chromium-depleted zones during the reactivation scan. Decreasing the scan rate exhibits an obvious effect on the breakdown of the passive film. A solution with 2 mol/L H2SO4+1 mol/L NaCl+0.01 mol/L KSCN is suitable to check the susceptibility to IGC of HNSS at a sensitizing temperature of 650-950℃ at a suitable scan rate of 1.667 mV/s. Chromium depletion of HNSS is attributed to the precipitation of Cr2N which results in the susceptibility to IGC. The synergistic effect of Mo and N is suggested to play an important role in stabilizing the passive film to prevent the attack of IGC.
    • loading

    Catalog


    • /

      返回文章
      返回