Cite this article as:

LI Fang-jun, WANG Guo-biao, and LU Wen, RESEARCH ON DISTRIBUTION PAIR OFBENT-AXIS PUMP, J. Univ. Sci. Technol. Beijing , 3(1996), No. 1, pp.48-54.
LI Fang-jun, WANG Guo-biao, and LU Wen, RESEARCH ON DISTRIBUTION PAIR OFBENT-AXIS PUMP, J. Univ. Sci. Technol. Beijing , 3(1996), No. 1, pp.48-54.
引用本文 PDF XML SpringerLink

斜轴泵配流副的理论与试验研究

摘要: 动态测试了斜轴泵配流副的油膜间隙。在综合考虑配流副泄漏量、功率损失和抗污染磨损能力的基础上,对描述配流副工作状态的参数进行了优化。根据理论分析和试验研究,对配流盘的结构进行了改进,增强了配流副的抗污染磨损能力,从而延长了泵的使用寿命,提高了泵的工作可靠性。

 

RESEARCH ON DISTRIBUTION PAIR OFBENT-AXIS PUMP

Abstract: The oil film thickness of the distribution pair of the bent-axis pump is tested dynamically in this paper. On the basis of synthetical consideration of the leakage flow rate, the loss of power and the ability to resist contaminant of the distribution pair,the parameters used to describe the distribution state are optimized. According to theoretical analyses and experimental research, the structure of the distribution plate is improved, and the ability to resist contaminant wear of the distribution pair is increased. Thus, it is possible to prolong the service life and working reliability of the pump.

 

/

返回文章